  • How to choose a good solenoid valve

    Classify:Technical information Release time:2024-10-31

    Selection criteria:


    1. Select the solenoid valve based on pipeline parameters: diameter specification (i.e. DN), interface method


    1) Determine the diameter (DN) size according to the on-site pipeline inner diameter size or flow requirements;


    2) Interface method, generally>DN50 requires flange interface, ≤ DN50 can be freely selected according to user needs.


    2. Select the material and temperature group of the solenoid valve based on fluid parameters


    1) Corrosive fluids: corrosion-resistant solenoid valves and all stainless steel should be selected; Edible ultra clean fluid: It is recommended to use food grade stainless steel solenoid valves;


    2) High temperature fluid: It is necessary to choose electromagnetic valves made of high-temperature resistant electrical materials and sealing materials, and to choose piston type structures;


    3) Fluid state: up to gaseous, liquid, or mixed state, especially when the diameter is greater than DN25, it must be distinguished;


    4) Fluid viscosity: Usually below 50cSt, it can be freely selected. If it exceeds this value, a high viscosity solenoid valve should be used.


    3. Selecting solenoid valves based on pressure parameters: principles and structural types


    1) Nominal pressure: This parameter has the same meaning as other general valves and is determined based on the nominal pressure of the pipeline;


    2) Work pressure: If the work pressure is low, the principle of direct action or step-by-step direct action must be selected; When the minimum working pressure difference is above 0.04Mpa, direct acting, step-by-step direct acting, and pilot operated can all be selected.


    4. Electrical selection: The voltage specifications should preferably be AC220V or DC24, which are more convenient.


    5. Choose based on the duration of continuous work: normally closed, normally open, or continuously powered on


    1) When the solenoid valve needs to be opened for a long time and the duration exceeds the closing time, the normally open type should be selected;


    2) If the opening time is short or the opening and closing time is not long, choose the normally closed type;


    3) However, for some working conditions used for safety protection, such as furnace and kiln flame monitoring, the normally open type cannot be selected, and the long-term electrified type should be selected.


    6. Select auxiliary functions according to environmental requirements: explosion-proof, check, manual, waterproof fog, water shower, and diving.


    Selection principle


    Security:


    1. Corrosive media: Plastic king solenoid valves and all stainless steel should be selected; For strongly corrosive media, isolation membrane type must be selected. Neutral media, it is also advisable to use copper alloy as the valve shell material for solenoid valves, otherwise rust debris often falls off from the valve shell, especially in situations where the action is not frequent. Ammonia valves cannot use copper materials.


    2. Explosive environment: Corresponding explosion-proof products must be selected, and waterproof and dustproof varieties should be selected for outdoor installation or in dusty environments.


    3. The nominal pressure of the solenoid valve should exceed the maximum working pressure inside the pipe.


    Applicability:


    1. Medium characteristics


    1) Select different types of solenoid valves for gas, liquid, or mixed states;


    2) Products with different specifications and medium temperatures may cause the coil to burn out and the sealing components to age, seriously affecting their service life;


    3) The viscosity of the medium is usually below 50cSt. If it exceeds this value and the diameter is greater than 15mm, use a multifunctional solenoid valve; When the diameter is less than 15mm, use a high viscosity solenoid valve.


    4) When the cleanliness of the medium is not high, a backwash filter valve should be installed in front of the solenoid valve. When the pressure is low, a direct acting diaphragm solenoid valve can be selected;


    5) If the medium flows in a directional manner and backflow is not allowed, it needs to flow in both directions;


    6) The medium temperature should be selected within the allowable range of the solenoid valve.


    2. Pipeline parameters


    1) Select valve ports and models based on the requirements of medium flow direction and pipeline connection method;


    2) Select the nominal diameter based on the flow rate and valve Kv value, or choose the same pipe inner diameter;


    3) Working pressure difference: Indirect pilot type can be used when the minimum working pressure difference is above 0.04Mpa; For those with a minimum working pressure difference close to or less than zero, direct acting or step-by-step direct acting must be selected.


    3. Environmental conditions


    1) The maximum and minimum temperatures of the environment should be selected within the allowable range;


    2) In environments with high relative humidity and water droplets and rain, waterproof solenoid valves should be selected;


    3) Special varieties should be selected for situations where there are frequent vibrations, bumps, and impacts in the environment, such as marine solenoid valves;


    4) When used in corrosive or explosive environments, priority should be given to selecting corrosion-resistant types according to safety requirements;


    5) If the environmental space is limited, a multifunctional solenoid valve should be selected because it eliminates the need for a bypass and three manual valves, and is easy to maintain online.


    4. Power supply conditions


    1) Select AC and DC solenoid valves according to the type of power supply. Generally speaking, AC power supply is easy to access;


    2) Voltage specifications should prioritize AC220V and DC24V as much as possible;


    3) The fluctuation of power supply voltage is usually selected as% -15% for AC, and ± for DC. If it exceeds the tolerance, voltage stabilization measures must be taken;


    4) The rated current and power consumption should be selected based on the power capacity. Attention should be paid to the high VA value during communication start-up, and indirect induction solenoid valves should be preferred when the capacity is insufficient.


    5. Control accuracy


    1) Ordinary solenoid valves only have two positions, on and off. When high control accuracy and stable parameter requirements are needed, multi position solenoid valves should be selected;


    2) Action time: refers to the time from when the electrical signal is turned on or off to when the main valve action is completed;


    3) Leakage rate: The leakage rate values given on the sample are commonly used economic levels.


    Reliability:


    1. The working life is not included in the factory test items, but belongs to the type test items. To ensure quality, branded products from reputable manufacturers should be selected.


    2. Work system: divided into three types: long-term work system, repeated short-term work system, and short-term work system. For situations where the valve is open for a long time but only closed for a short time, it is advisable to use a normally open solenoid valve.


    3. Working frequency: When the operating frequency requirement is high, the structure should preferably use a direct acting solenoid valve, and the power supply should preferably use AC.


    4. Action reliability


    Strictly speaking, this test has not yet been officially included in the professional standards of Chinese solenoid valves. To ensure quality, branded products from reputable manufacturers should be selected. In some situations where the number of actions is not high, but the reliability requirements are very high, such as fire protection, emergency protection, etc., we must not take it lightly. It is particularly important to adopt dual insurance for two consecutive uses.


    Economy:


    It is one of the selected scales, but it must be economical based on safety, applicability, and reliability.


    Economy is not only about the price of the product, but also about prioritizing its functionality and quality, as well as the cost of installation, maintenance, and other accessories.


    More importantly, the cost of a single solenoid valve in the entire control system and even in the production line is negligible. If one chooses the wrong one for the sake of small gains, it can cause huge damage to the group.


    Related information

    View more
    View more
    View more
    主站蜘蛛池模板: 亚洲av中文无码乱人伦| 免费观看又污又黄的网站| 西欧free性video| 国产免费一区二区三区免费视频| 午夜福利92国语| 无码国产精品一区二区免费虚拟vr| 视频一区视频二区制服丝袜| 老师课后辅导乳揉搓h在线观看| 3d动漫精品啪啪一区二区下载| 天堂中文www| 空之色| 疯狂添女人下部视频免费| 青青草97国产精品免费观看| 精品露脸国产偷人在视频| 色播久久人人爽人人爽人人片av| 国产重口老太和小伙乱| 99久久伊人精品综合观看| 啦啦啦啦在线视频免费播放6| 中国毛茸茸性xxxx| www.成色av久久成人| 欧美大屁股xxxxhd| 寡妇张开腿让黑人捅爽| 中文字幕 制服 亚洲 另类| 中文字幕亚洲无线码在线一区| 国语自产少妇精品视频蜜桃| 国产69精品久久久久9999| 99久久综合狠狠综合久久aⅴ| 久久久久久久综合日本| 性少妇freesexvideos高清| 国产手机在线αⅴ片无码观看| а√天堂资源地址在线官网| 亚洲色自偷自拍另类小说| 老女人做爰全过程免费的视频| 老师露双奶头无遮挡挤奶视频| 欧美性狂猛xxxxx深喉| 日本新japanese乱熟| 久久婷婷久久一区二区三区| 免费观看日本污污ww网站| 少妇私密会所按摩到高潮呻吟| 久久尤物av天堂日日综合| 日本一区二区三区高清无卡|